Contact our teamProjects, solutions, and collaborations→
Home / Project / Data Center

Data Center

We design, build, and equip data centers and server rooms for enterprises and government organizations. Our capabilities and services cover the essential infrastructure required to support modern computing environments.

Data Center

We design, build, and equip data centers and server rooms for enterprises and government organizations. Our capabilities and services cover the essential infrastructure required to support modern computing environments.

Most organizations do not plan their server rooms. Unplanned, ad-hoc infrastructure expansion fundamentally compromises system integrity. Improper spatial management, inadequate climate control, and undocumented cabling create critical vulnerabilities. These unoptimized environments inevitably guarantee downtime through thermal overload, power disruption, or unresolvable system faults.

A data center is the answer to that risk. Purpose-built data centers eradicate infrastructural liabilities through holistic engineering and absolute redundancy. TAP executes the deployment of these mission-critical facilities under a single contract, managing everything from civil works to final commissioning to guarantee uninterrupted operations.

Purpose-Built Facilities

Four Conditions Engineered In

Server equipment concentrates heat and power demand in a way ordinary buildings were never designed for. TAP engineers each facility for four conditions before the equipment arrives.

Condition

Heat

A loaded rack produces more heat than several comfort air conditioners can remove. Precision cooling and planned airflow keep every server inside its operating range.

Precision cooling and aisle containment
Condition

Power

An unstable grid makes conditioned, redundant power the first requirement of any facility in Pakistan. UPS and generator systems carry the load through every interruption.

N+1 UPS, generator and conditioned distribution
Condition

Fire & Water

Server environments need early detection and suppression that extinguishes fire without harming live electronics, plus protection against leaks.

Early smoke detection and clean-agent suppression
Condition

Visibility

Sensors for temperature, humidity, power and access turn silent risks into alarms that reach staff before users notice anything.

Environmental and infrastructure monitoring

One Contract, One Engineered Facility

TAP delivers Data Center

Every facility starts with a load assessment. We calculate the power and heat each rack will produce on day one and after planned growth, then design the room around those numbers. Layouts, cooling capacity, and electrical sizing follow the TIA 942 standard and Uptime Institute tier principles, matched to the availability level your operations and budget justify.

We then deliver the full construction scope. Civil works, raised flooring, precision cooling, UPS systems with N+1 redundancy, generator integration, power distribution, racks, structured cabling, early smoke detection, clean agent fire suppression, access control, and CCTV are installed by our teams and our specialist partners under a single TAP contract.

Every system is strictly validated against design specifications prior to final handover. Commissioning protocols dictate comprehensive stress testing, including simulated power failures, UPS module redundancy checks, and thermal stability verification. We complete the deployment with full documentation, technical training, and integrated maintenance protocols.

Redundancy Design

Availability Matched to Your Operations

Redundancy is agreed with you before any equipment is ordered, so the facility delivers the availability you need without paying for capacity you do not.

LevelConfigurationTypical application
NCapacity equal to the loadSmall server rooms where planned downtime for maintenance is acceptable.
N+1One spare componentEnterprise server rooms that must stay online through a single component failure.
2NTwo complete systemsCritical facilities requiring maintenance without interrupting the load.
2N+1Two systems plus a spareMission-critical government and financial facilities with the highest availability needs.

What We Deliver

Every Layer of the Facility

Engineered layers make up a complete data center, each designed to the same load assessment and standard.

Power Systems

UPS systems in N+1 configuration, power distribution units, generator integration and earthing, engineered for an unstable grid.

  • Modular UPS
  • Automatic transfer switching
  • Generator integration
  • Rack PDUs
  • Earthing and bonding
  • Surge protection

Precision Cooling

Computer room air conditioning, row-based cooling and aisle containment that keeps supply air where the servers need it.

  • CRAC and CRAH units
  • In-row cooling
  • Hot and cold aisle containment
  • Raised floor airflow
  • Humidity control
  • Redundant cooling units

Racks & Cabling

Server racks, cable trays and structured copper and fiber cabling, installed, labeled and documented to standard.

  • Server and network racks
  • Overhead cable trays
  • Copper cabling
  • Fiber cabling
  • Patch panels
  • Labeling and records

Fire Protection

Early smoke detection and clean-agent suppression systems that stop fire without water and without damaging live equipment.

  • Very early smoke detection
  • Clean-agent suppression
  • Fire alarm integration
  • Leak detection
  • Emergency power off
  • Signage and procedures

Security & Access

Biometric and card access control, CCTV coverage and logged entry, so only authorized staff reach the equipment.

  • Biometric access
  • Card readers
  • CCTV coverage
  • Logged entry
  • Rack-level locks
  • Visitor management

Monitoring

Environmental sensors and monitoring software that track temperature, humidity, power and access, and alert staff the moment a value drifts.

  • Temperature sensors
  • Humidity sensors
  • Power metering
  • Door and access events
  • SMS and email alerts
  • Capacity dashboards

Design Standards

Designed to Recognized Standards

TAP’s data center designs reference internationally recognized standards for infrastructure, thermal management, fire protection and efficiency.

TIA-942

Data center telecommunications infrastructure

Uptime Institute Tiers

Availability and redundancy classification

ASHRAE TC 9.9

Thermal guidelines for IT equipment

NFPA 75 & 2001

IT equipment protection and clean-agent systems

TIA-568 · 606 · 607

Cabling, labeling, bonding and grounding

PUE

Power usage effectiveness as an efficiency measure

Commissioning

Tested Under Load Before Handover

Commissioning follows a staged program, from factory witness tests to an integrated test of the whole facility under simulated load and failure.

Level 1

Factory Tests

Major equipment tested at the manufacturer before shipment.

Level 2

Installation Checks

Every unit inspected for correct installation on site.

Level 3

Start-Up

Systems energized and started to manufacturer procedures.

Level 4

Functional Tests

Each system tested against its design performance.

Level 5

Integrated Test

Simulated load, power failures and cooling failover across the facility.

Technologies

Leading Manufacturers Across Every Layer

TAP selects equipment from established manufacturers for each project, against the specification, the site and the budget.

Power & Cooling

  • Schneider Electric
  • APC
  • Vertiv
  • Eaton

Racks & Enclosures

  • Rittal

Servers & Infrastructure

  • Hewlett Packard Enterprise
  • Dell
  • Huawei

The TAP Way

How We Deliver, and the Impact on Your Operations

Each stage of the method produces a lasting benefit for the facility and the organization it serves.

01
How we deliver

We survey the site and calculate the real power and heat load, for day one and for the growth you plan.

Business impact

Services Stay Up

Redundant power and cooling absorb grid failures and equipment faults without taking systems offline.

02
How we deliver

We design to TIA-942 and tier principles, and agree the redundancy level with you before any equipment is ordered.

Business impact

Costs Stay Predictable

Right-sized cooling and efficient power systems hold down the electricity bill for the life of the facility.

03
How we deliver

Our teams and specialist partners execute the civil, electrical, mechanical and network works under one TAP contract.

Business impact

Audits Pass

Controlled access, logged entry, fire protection and complete documentation satisfy regulators and internal auditors.

04
How we deliver

We test every system under load and on generator, then hand over with documentation, training and a maintenance contract.

Business impact

Growth Is Planned

Space, power and cooling headroom are designed in, so adding racks is a schedule item rather than a crisis.

Related

Works Together With

ICT

ICT Systems & Infrastructure

The complete ICT portfolio.

View →
ICT

Computer Hardware

Servers, storage and network equipment.

View →
ICT

Data Integration

The central store your facility hosts.

View →
ICT

Customer Relationship Management

Applications running on your infrastructure.

View →