Power protection, energy metering, enclosures and supporting infrastructure that keep every ITS system running efficiently and reliably.
We integrates the infrastructure on which every ITS system depends: uninterruptible power for stations and equipment rooms, smart energy metering and energy management, environmental control for server rooms, protective equipment enclosures, earthing and grounding, solar support, and the asset tagging and field tools that keep equipment maintained.
Energy management gives operators near-real-time transparency over electricity, generator and alternate-source consumption across the network, with alarms for abnormal conditions and the data needed to reduce energy use and prevent fuel losses.
Power Path
Continuous Power from Source to Equipment
Every critical ITS device is protected by a controlled power path. Supply is metered, distributed and conditioned through uninterruptible power before it reaches equipment, so a supply interruption never becomes a service interruption.
- 01
Supply
Utility grid as the primary source, with standby generators and solar support at suitable locations.
- 02
Metering
Smart energy meters record consumption and power quality at key electrical points.
- 03
Distribution
Protected distribution boards with master breakers and sub-metering by area and system.
- 04
Conditioning
UPS systems deliver clean, uninterrupted power and bridge supply changeovers.
- 05
Equipment
Every connected ITS device runs on protected power, with earthing to a common ground point.
- Protected LoadStation data cabins
- Protected LoadPoE cameras, speakers and phones
- Protected LoadFare collection equipment
- Protected LoadControl center and servers
Power & Environment
Power Protection and Environmental Control
TAP specifies power protection and cooling for every location where ITS equipment is housed.
| Uninterruptible power | UPS systems sized to carry all equipment in each station data cabin, including PoE-powered cameras, speakers and phones |
|---|---|
| Control center and data center | Redundant UPS for servers, storage, network and operator positions |
| Server-room cooling | Dedicated air conditioning for station server rooms and equipment rooms |
| Earthing and grounding | Protective earthing of all enclosures, racks and equipment to a common ground point |
| Solar support | Solar-supported power systems for suitable locations |
| Sub-metering | Metering at distribution points to attribute consumption by area and system |
Energy Management
Energy Use Across the Network, in One View
The energy management system consolidates meter data from every station, depot and the control center, so operators can see where energy is used, compare sources and act on abnormal conditions.
- 01
Grid Consumption
Energy drawn from the utility grid, reported by station, depot and system, with daily, monthly and peak-demand views for budgeting and tariff management.
- 02
Generator Usage
Generator running hours and energy produced at each site, so standby operation is visible and verified against supply interruptions.
- 03
Fuel Consumption
Fuel use estimated from generator output and compared across sites, giving operators the data to identify losses and control fuel expenditure.
- 04
Power Quality
Continuous logging of voltage, current, frequency and power factor, so electrical issues are identified before they affect equipment.
- 05
Reports and Analytics
Scheduled and on-demand reports comparing sites, periods and sources, supporting energy-reduction targets and accountability at every location.
Alarms and Notifications
- Consumption above threshold
- Voltage or frequency out of range
- Low power factor
- Generator start and run time
- UPS on battery
- Meter communication loss
Outcomes
What Energy Management Delivers
Energy data becomes a tool for efficiency, accountability and reliability.
Transparency
Accountability for energy and fuel use at every location.
Efficiency
Granular energy-flow data that shows where consumption can be reduced.
Power Quality
Continuous logging of key electrical parameters.
Fuel Control
Generator monitoring and fuel comparisons to prevent losses.
Enclosures
Enclosures Matched to Every Environment
TAP specifies equipment housings for the conditions at each installation point, from open-air corridors to climate-controlled rooms, with particular attention to hot and humid climates.
| Aspect | Outdoor (no roof) | Covered outdoor | Indoor, controlled | Handheld devices |
|---|---|---|---|---|
| Ingress protection | IP65 | IP52 | Not required | IP65 |
| Construction | Stainless-steel class casing, concealed fixings | Impact- and corrosion-resistant casing | Standard racks and cabinets | Rugged housing |
| Climate provision | Internal temperature and humidity control | Ventilation for heat and humidity | Room air conditioning | Rated for outdoor use |
| Electrical safety | Master breaker and grounding | Master breaker and grounding | Grounded racks | Rechargeable, protected battery |
Equipment Gallery
The Power & Infrastructure Range

UPS System

Smart Energy Meter

Energy Dashboard

Server-Room Cooling

Outdoor Enclosure

Solar Support

Asset Tags

Rugged Tablet
One Partner for the Foundations
Protected
UPS on every critical device.
Measured
Smart meters at key electrical points.
Efficient
Energy data that reduces consumption.
Durable
Enclosures matched to each environment.
Supported
Installation and maintenance by TAP.
Related ITS Solutions
Hardware & Software
Management
Comments are closed